TCC Module
The standard TCC module is a NI PCI-6503 24 channel digital in/out card. The 24 channels are grouped by 3 ports á 8 lines. This card is also used for the UPS. For the TCC port 0 / lines 0 - 7 is used. For the UPS port 1 / line 0 is used.
A temperature chamber contact module has the following mandatory standard parameters:
| Parameter | Meaning | Examples |
|---|---|---|
| Resource | The connection information needed to connect to this device. | cDAQ1Mod1/port0/line0:7 |
| Inverted | Indicated whether the digital inputs are inverter or not. The standard LTT TCC hardware has inverted inputs. | true / false |
| LastSimValue | This parameter is used by the simulation driver to store the last simulated value. You change this value via the TCC control panel. | 1 |
You can access a TCC control panel through GUI and also via TestStand.